Video
Loading video...

📄 Journal Article

The Numerical Study of Base-Isolated Buildings Under Near-Field and Far-Field Earthquakes

March 15, 2017 107 citations 🔒 Closed Journal of Earthquake Engineering
107
Citations
4
Authors
32
References
1
Countries
Abstract

The behavior of base-isolated building frame is investigated with the help of a numerical study for far-field and near-field earthquakes with directivity and fling-step effects. Both design-level and extreme-level earthquakes are considered. Selected response parameters are peak floor displacement, acceleration, base shear, and isolator displacement. Inelastic behavior of base-isolated structure during the earthquake is investigated performing nonlinear time history analysis of a ten-story building frame. This study shows that base isolation is not effective for near-field earthquakes. Even for design-level earthquake, the frame gets significantly into inelastic range for earthquakes with fling-step effect.

Publication Details
TypeJournal Article
PublishedMarch 15, 2017
Source Journal of Earthquake Engineering
PublisherTaylor & Francis
Volume/Issue Vol. 22 , Issue 6 , pp. 989-1007
DOI 10.1080/13632469.2016.1269698
OpenAlex ID W2621031353
Open AccessClosed Access
Sustainable Development Goals
11 11