The Numerical Study of Base-Isolated Buildings Under Near-Field and Far-Field Earthquakes
The behavior of base-isolated building frame is investigated with the help of a numerical study for far-field and near-field earthquakes with directivity and fling-step effects. Both design-level and extreme-level earthquakes are considered. Selected response parameters are peak floor displacement, acceleration, base shear, and isolator displacement. Inelastic behavior of base-isolated structure during the earthquake is investigated performing nonlinear time history analysis of a ten-story building frame. This study shows that base isolation is not effective for near-field earthquakes. Even for design-level earthquake, the frame gets significantly into inelastic range for earthquakes with fling-step effect.
| Type | Journal Article |
|---|---|
| Published | March 15, 2017 |
| Source | Journal of Earthquake Engineering |
| Publisher | Taylor & Francis |
| Volume/Issue | Vol. 22 , Issue 6 , pp. 989-1007 |
| DOI | 10.1080/13632469.2016.1269698 |
| OpenAlex ID | W2621031353 |
| Open Access | Closed Access |