Transient Analysis of Self-Excited Induction Generator With Electronic Load Controller (ELC) Supplying Static and Dynamic Loads
This paper presents a transient analysis of a self-excited induction generator (SEIG) with electronic load controller (ELC) used in stand-alone micro-hydro power generation employing uncontrolled turbines. In view of the need to feed both dynamic [three-phase induction motor (IM)] and static loads from such systems, the transient behavior due to switching in of such loads is of interest and is carried out here. A composite mathematical model of the total system has been developed by combining the modeling of prime mover, SEIG, ELC, and load. Simulated results are compared with the experimental ones, obtained on a developed prototype of an SEIG-ELC system for the starting of an IM and switching in a resistive load. For the starting of an IM, a star/delta starter is used to avoid inrush current. Harmonic analysis is carried out to find total harmonic distortion of the terminal voltage and current to assess its power quality.
| Type | Journal Article |
|---|---|
| Published | September 01, 2005 |
| Source | IEEE Transactions on Industry Applications |
| Publisher | Institute of Electrical and Electronics Engineers |
| Volume/Issue | Vol. 41 , Issue 5 , pp. 1194-1204 |
| DOI | 10.1109/tia.2005.855047 |
| OpenAlex ID | W2048140044 |
| Open Access | Closed Access |