Video
Loading video...

📄 Journal Article

Design, simulation and implementation of three-pole/four-pole topologies for active filters

June 11, 2004 124 citations 🔒 Closed IEE Proceedings - Electric Power Applications
124
Citations
5
Authors
15
References
3
Countries
Abstract

Three-pole/four-pole topologies of current-controlled voltage source inverters (CC-VSI) used as active filter (AF) are considered. The proposed AF system employs power balance theory, which is implemented using a TMS320C31 DSP. A four-pole topology for the AF system exhibits the facility of operating it as a three-pole device. A prototype model of the AF system has been designed and tested with a non-linear load to demonstrate its effectiveness for harmonic elimination, reactive power compensation and power-factor correction. After the control scheme was verified through extensive experimental investigations on a three-pole AF system, it was applied to demonstrate the performance of a four-pole AF system through simulation with different possibilities for the non-linear loads in field applications. Simulation and experimental results of the developed model of the AF system are given and discussed in detail.

Publication Details
TypeJournal Article
PublishedJune 11, 2004
Source IEE Proceedings - Electric Power Applications
PublisherInstitution of Engineering and Technology
Volume/Issue Vol. 151 , Issue 4 , pp. 467-476
DOI 10.1049/ip-epa:20040209
OpenAlex ID W2007105645
Open AccessClosed Access
Sustainable Development Goals
7 7